- 2-wire compact transmitter
- Accuracy: ±5 or ±20 mm
- Measuring range up to 24 m
- High pressure
- High temperature range
- Wide range of probes
- Extremely low dead band
- 20-point linearisation
- HART communication
- Rod or cable probes
- Plastic, aluminium or stainless steel housing
- Plug-in graphic display module
- Explosion-proof models
MicroTREK with rod probe
- 2-wire compact TDR level transmitter for liquids and free-flowing solids
- With stainless steel mono or twin rod probe with or without plastic coating
Version/Temperature |
Transmitter/Flange Temp max 90°C, Transmitter/Flange Temp max 200°C (St/St Probe Only), Transmitter with LCD Display/Flange Temp max 90°C, Transmitter with LCD Display/Flange Temp max 200°C (St/St Probe Only) |
---|---|
Probe/Process Connection |
Mono rod, 1.4571 / 1" BSP / max. 3 m, Mono rod, 1.4571 / 1" NPT / max. 3 m, Twin rod, 1.4571 / 1 1/2" BSP / max. 3 m, Twin rod, 1.4571 / 1 1/2" NPT / max. 3 m, Mono rod + PFA coated / DN50, PN25, 1.4571+PFA lining, Mono rod + PP coated / DN50, PN25, 1.4571+PP lining, Mono rod + PFA coated / 1 1/2" Triclamp PFA coated |
Housing |
Aluminium (paint coated), Plastic, PBT, glass fibre reinforced (Ex version not available; HT, HB only), Stainless steel |
Probe Lenght |
1.0-3.0 m (each 0.1 m), for mono rod, 1.4571, 1.0-3.0 m (each 0.1 m), for mono rod, PP coated, 1.0-3.0 m (each 0.1 m), for mono rod, PFA coated, 1.0-3.0 m (each 0.1 m), for twin rod, 1.4571 |
Output/Ex |
4-20 mA + HART, 4-20 mA + HART / Ex tD (only for HT, HB and probes without coating), 4-20 mA + HART / Ex iaD, 4-20 mA + HART / Ex ia |
Specifications
Power supply:                           20 – 36 V DC
Ambient temperature:                   -20 °C … +60 °C
Process temperature:                    -30 °C … +100 °C
Pressure:                               -1 bar – 3 bar
Output:                                4 – 20mA, HART
Process connection:                     1 ½”, 2″ or flanges or sanitary
Protection:IP68Approvals:ATEX, IEC Ex
Applications
- Level, volume measurement
- Liquids, powders and granular mediums with εr>1.4
- Medium with turbulent surface, dense dust, vapour or pressurized gas layers above the product surface
- For all tank shapes, for narrow vessels
- Heavy industrial applications
Resources
Brochures
Operating Instructions