- 2-wire compact transmitter
- Rod or cable probes up to 20 m
- Plug-in display module
- Fully or partly insulated probes
- Secondary lightning protection
- Plastic, aluminium or stainless steel housing
- Distance, level and volume measurement
- 32 point linearisation
- High sensitivity
- HART communication
- Explosion proof models
NIVOCAP C with Cable probe
- 2-wire compact capacitance level transmitter for conductive and non-conductive liquids
- With partially or fully plastic coated stainless steel rod probe
Version/Temperature |
Transmitter / 130°C, Transmitter with local LCD indicator / 130°C |
---|---|
Process connection size / Insulation |
1" BSP / Fully FEP insulated steel, 1½" BSP / Fully FEP insulated steel, 1" NPT / Fully FEP insulated steel, 1½" NPT / Fully FEP insulated steel |
Housing |
Aluminium (paint coated), Plastic, PBT, glass fibre reinforced (Ex version not available; HT, HB only), Stainless steel |
Probe length |
2 – 20 m; each started 100 mm |
Insulation |
Fully FEP insulated, Partially FEP insulated |
Output/Ex |
4-20 mA + HART, 4-20 mA + HART / Ex tD (only for HT, HB and probes without coating), 4-20 mA + HART / Ex iaD, 4-20 mA + HART / Ex ia |
Special Request |
½ " Triclamp (ISO 2852), 2" Triclamp (ISO 2852), DN 40 Pipe coupling (DIN 11851), DN 50 Pipe coupling (DIN 11851) |
Brand |
Nivelco |
Specifications
Power supply: 20 – 36 V DC
Ambient temperature: -20 °C … +60 °C
Process temperature: -30 °C … +200 °C
Pressure: -1 bar – 3 bar
Output: 4 – 20mA, HART
Process connection: 1 ½”, 2″ or flanges or sanitary
Protection: IP67
Approvals: ATEX, IEC Ex
Applications
- Level measurement of conductive and non-conductive materials
- Liquids, powders, granules with εr>1.5 relative dielectric constant
- Chemicals with dense gas layers above the surface
- Viscose or corrosive mediums
- High pressure, high temperature or vacuum
Resources
Brochure
Operating Instructions