- 2-wire compact and mini compact transmitter
- 0.1 mm or 1 mm resolution
- Plug-in display module
- Rigid or flexible probes up to 15 m
- Wetted parts: stainless steel or plastic
- Distance, level and volume measurement
- 99 point linearisation
- HART communication
- Explosion-proof models
- OIML R85 certification
NIVOTRACK M-500/M-600 with Flexible probe
- 2-wire compact magnetostrictive level transmitter for liquids
- With stainless steel cable probe and weight with 0.1 mm or 1 mm resolution
Version |
Transmitter, Transmitter with local LCD indicator |
---|---|
Process Connection |
2" BSP, 2" NPT |
Housing |
Aluminium (paint coated), Plastic, PBT, glass fibre reinforced (Ex version not available), Stainless steel |
Probe Lenght |
Specify length in m (max 15m) |
Output/Resolution/Approval |
4-20 mA / 0.1 mm, 4-20 mA / 1 mm, 4-20 mA + HART / 0.1 mm, 4-20 mA + HART / 1 mm, 4-20 mA / 0.1 mm / Ex ia, 4-20 mA / 1 mm / Ex ia, 4-20 mA + HART / 0.1 mm / Ex ia, 4-20 mA + HART / 1 mm / Ex ia, 4-20 mA / 0.1 mm / Ex d (up to 10 m), 4-20 mA + HART / 0.1 mm / Ex d (up to 10 m), 4-20 mA / 0.1 mm / Ex d + Ex ia (up to 10 m), 4-20 mA + HART / 0.1 mm / Ex d + Ex ia (up to 10 m) |
Cable Lenght |
Specify cable length ≤300 meters |
Brand |
Nivelco |
Specifications
Power supply:                           12 – 30 V DC
Ambient temperature:                   – 40 °C … + 70 °C
Process temperature:                    -40 °C … +90 °C
Output:                                4 – 20mA, HART
Pressure:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â max. 25 bar
Measuring Range                       0 – 3 meters
Process connection:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 1″, 2″ or flanges
Protection:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â IP67
Approvals:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â ATEX ex, IEC Ex, FM, CSA, OIML R-85
Applications
- Liquids with min. 0.4 kg/m3 density
- Chemicals, solvents, hydrocarbons
- Flammable liquids
- Interface metering
- Custody transfer (OIML R-85)
Resources
Brochures
Operating Instructions